Available Photonics Experiments:

P5862 Diode pumped Nd:YAG Laser (DPSSL)
PDF Download page

  • Properties of diode laser
  • Nd:YAG crystal
  • Optical pumping
  • Rate Equation Model
  • Static and dynamic solution
  • Laser output power
  • Laser resonator
  • Transversal modes
  • Cavity stability criterion
  • Spiking
XP-06
  • Principle of operation
The radiation of the diode laser (A) is focused by means of the collimator(B) and lens (C) into the Nd:YAG rod (D). The laser cavity is formed by the coating (1) of the rod and the mirror (2). The filter RG1000 (F) absorbs the residual pump light and transmits the laser radiation. The relative intensity is measured by the photodetector (G)
YAG layout
  • Examples of investigations and measurements
XP-06.01 Characterization of the diode laser
In a basic set-up the characteristic parameters of the laser diode are measured. The diode laser is mounted into a housing (9) in contact with a Peltier element to control the temperature. The full digitally controller (2) sets and maintains the value for injection current, temperature and modulation frequency of the diode laser (9). The characteristic data of the diode laser is measured in relative units. For this purpose the signal conditioner (3) is used. The photodiode (14) is connected to this box where the input impedance can be selected. The output is available at a BNC connector for further connection to an oscilloscope or multimeter. The collimator (9) is used to set the beam divergence in such a way that the photodetector will not be saturated.
XP-06.02 Optical pumping and spectroscopy
To the previous set-up the focussing lens (10) and the Nd:YAG rod (11) with its holder are added. The transmission spectrum of the laser diode radiation is measured by changing the temperature and therewith the emission wavelength. By means of the well known absorption lines the emission wavelength of the laser diode can be determined exactly. Adding the filter RG1000 (7) in front of the detector blocks the diode laser radiation and the fluorescence caused by optical pumping can be measured as function of the pump laser wavelength (temperature). At the maximum of the fluorescence emission the modulation of the diode laser is activated and the timely response displayed on an oscilloscope. From this curve the mean lief time of the exited laser state of the Nd:YAG material can be derived which inverse value represents the important Einstein coefficient for spontaneous emission.
XP-06.03 Laser operation
Adding the second cavity mirror (12) to the set-up and aligning it properly laser oscillation at the wavelength of 1064 nm is obtained. The optimum laser parameters with respect to pump power and wavelength are ascertained. The laser threshold and efficiency are determined and by modulating the pump laser diode the so called spiking effect demonstrated. By changing the length of the laser cavity the stability criterion is verified. This is accomplished by moving the adjustment holder (12) and reading its position with respect to the holder (11) containing the Nd:YAG rod including the coating for cavity mirror (1).
  • P5862 Diode pumped Nd:YAG Laser (DPSSL) consisting of:
ItemCodeQtyDescription
13L-0200 2BNC cable, BNC connector on both sides, length 1,5 m
2ED-00201Digital controller for injection current and temperature
3ED-00601Photodetector signal conditioning box
4MC-00051Profile rail MG-65, 500 mm
5MC-01201Crossed hair target in holder 25 mm
6PM-00701Infrared display card, range 0.8 -1.6 µm
7PM-02501RG1000 Coloured glass filter 50x50x4 mm
8XM-00201Module A - Diode laser in adjustment holder
9XM-00301Module B - Collimating optics on carrier
10XM-00401Module F - Focussing optics, f=60 mm
11XM-00501Module D - Mirror adjustment holder with Nd:YAG rod
12XM-00601Module E - Adjustment holder “right” with laser mirror SHG 100
13XM-00701Module F - Filter plate holder
14XM-00801Module G - SiPIN photodetector
15XM-02201Optics cleaning set
Required Option:
 TP-01001Oscilloscope 100 MHz digital, two channel